About 106,000 results
Open links in new tab
  1. What are the Pros & Cons of a generator transfer switch vs an interlock?

    Jan 17, 2024 · I'd like to be able to power essential circuits with a portable generator. If local code allows, I could use either a manual generator transfer switch (I'm looking at the Reliant Controls …

  2. electrical - Are generator interlock kits permitted in residential ...

    Are generator interlock kits permitted in residential applications? Ask Question Asked 12 years, 11 months ago Modified 8 years, 2 months ago

  3. How to wire subpanel back to back for portable generator

    Mar 24, 2021 · You'll need the panel you recently acquired, a Reliance PK50 inlet kit to provide a place to plug the generator into, some 6AWG THHN (black/white/green) to connect the inlet to the …

  4. Bonded vs unbonded generator when running your main utility panel …

    Sep 8, 2021 · Your interlock does not switch neutral. Neutral and ground are connected to the generator anytime it's plugged in, even when you are on "utility" mode. Normally when an appliance has a …

  5. electrical - Bonded neutral generator - connecting to house and ...

    Apr 4, 2022 · 5 You can't use an interlock with a bonded neutral generator Since you need that main panel bond to be there in order to have a solid neutral-ground bond while on utility power (NEC …

  6. wiring - Can I have an interlock hooked up to the single main breaker ...

    Apr 5, 2023 · Into 2 of the breaker spaces goes your generator interlock. This is DIYable, but you'd need to have the power company "pull the meter" (typically done remotely using a big contactor inside the …

  7. electrical - Wiring for an emergency generator interlock - Home ...

    Oct 22, 2020 · You could stick the generator breaker in one of the normal spaces and use a standard factory interlock, then feed the big panel off the "feed-through lugs". The only problem is, the boxes …

  8. generator - What is the difference between an interlock and a transfer ...

    Nov 2, 2015 · An interlock needs a human to operate it. They cost less, in general. A transfer switch can be (and usually is) automatic. They cost more, in general. An interlock setup can usually feed power …

  9. How can I use a 120v generator to power both legs of my electrical ...

    Jul 23, 2020 · I was recently gifted a Champion brand, 3550 watt, 120 v generator. I had intended on hooking it up to my electrical panel via generator plug inlet box and interlock kit, but after doing some …

  10. electrical - Can I connect a portable generator to a subpanel to ...

    The generator is portable - when you need it, move it, and provide enough cord from a proper interlocked input on the main panel to connect to it. Or, run new wire all the way to where you want it …